BEA-320031 - An attempt to add a monitor of type monType to instrumentation scope scopeName failed because the monitor already exists in the scope.

Description:
Attempt to add duplicate monitor to an instrumentation scope failed. New monitor is ignored.

Cause:
Incorrect instrumentatation configuration

WL92-Diagnostics ,

BEA-320071 - Error occurred while creating watch notification watchName. Notifications may not have completed for this watch.

Description:
An exception was thrown while creating the watch notification.

Cause:
Exception thrown while creating the watch notification.

WL92-Diagnostics , ,

BEA-320111 - Could not add MBean instance instanceName to the harvested instance list for type typeName: cause.

Description:
The specified instance could not be added to the list of Harvested instanced for the specified type. Therefore the problematic instance cannot be harvested. Note that the instance remains removed until the configuration is reloaded at which time this message may appear again if the problem is not corrected.

Cause:
The actual problem occured at a previous point in time. Sufficient messages should have been issued at the point of failure to facilitate debugging the problem.

WL92-Diagnostics , ,

BEA-320043 - Image notification was not performed because the image capture was attempted before the lockout time expired. The exception message is exc

Description:
The notification attempted an image capture before the lockout period had completed.

Cause:
An image capture was attempted before the lockout period had expired.

WL92-Diagnostics ,

BEA-320084 - The user user does not have authorization to view the logs.

Description:
The user is not granted one of the Admin roles.

Cause:
A user with insufficient authorization attempted to access the server logs.

WL92-Diagnostics ,

BEA-320021 - Code generator className could not be accessed for standard monitor monitorName.

Description:
Internal error. Standard monitor code generator could not be accessed.

Cause:
Standard monitor code generator implementation has problems

WL92-Diagnostics

BEA-320055 - Could not read or create index on log file file

Description:
Could not read or create index on log file

Cause:
Disk may be full or directory is not writable

WL92-Diagnostics , , ,

BEA-320097 - Monitor type can be created only in an application instrumentation scope. It can not be created in server instrumentation scope.

Description:
Attempt to create a monitor in server scope, which can only be created in application scope.

Cause:
Attempt to create a monitor in server scope, which can only be created in application scope.

WL92-Diagnostics

BEA-320032 - Attempt to attach incompatible action of type actType to a delegating monitor of type monType in scope scopeName.

Description:
Attempt to attach incompatible action to a delegating monitor

Cause:
Incorrect instrumentation configuration

WL92-Diagnostics

BEA-320072 - Error while locating a record for timestamp timestamp in the archive

Description:
Error locating a record in the archive

Cause:
Misconfigured or missing data archive for harvested data

WL92-Diagnostics ,